fuel_s1_fcp
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: Obtain fuel keys, BA set, Bushfire Jacket or Fuel Controller Tabard, DSU, Radio. Take to Fuel Control Point (FCP) being utilized for the scenario., type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
, ...1 more...
)
fuel_s1_cell1
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: Starting at Cell 1 and checking all FCP's back to the Main Control Panel (MCP), ensure all fuel valves and solenoids in a closed position., type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
, ...1 more...
)
fuel_s1_pressure
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: Ensure air pressure is registered on the two gauges in the fuel valve corridor (FVC)., type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
, ...1 more...
)
fuel_s1_mcp
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: At MCP ensure Emergency Air Valves are closed. Turn on required fuels., type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
, ...1 more...
)
fuel_s1_leak_main
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: Run the gas leak detector (Bacharach) from main valves to the FCP via FVC and pipe alley ensuring there are no leaks, particularly at gate valves, pipe joins and junctions., type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
, ...1 more...
)
fuel_s1_leak_fcp
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: Run the gas leak detector (Bacharach) at FCP supply gate valves, open fuel to FCP via solenoids. Ensure there is no leaks leave the Bacharach running at FCP to monitor for any leaks., type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
, ...1 more...
)
fuel_s1_bucket
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: Obtain bucket with starting rags and MAPP torch for lighting props and the hand bin for used rags, place at FCP. Advise Scenario Manager preparations complete., type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
, ...1 more...
)
fuel_s2_wind
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: Determine wind direction and adjacent cell operations, don bushfire jacket or tabard ensuring DSU is activated and fitted. Ready BA set and don if required., type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
, ...1 more...
)
fuel_s2_radio
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: Radio test to Scenario Manager. Confirm required props are ready and fuel type to be used, confirm "All fuels Off", type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
, ...1 more...
)
fuel_s2_operate
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: Operate props as required by Scenario Manager. At all times hands are to be on valves of operating props and attention paid to Scenario Manager., type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
, ...1 more...
)
fuel_s2_off
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: Whenever all prop valves are shut off the cell fuel control valve are to be shut off as well, for emergency shut down of multiple props, shut off cell fuel control valve first., type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
, ...1 more...
)
fuel_s3_breaks
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: At final shutdown or breaks of ½ an hour or more, completely shut down the fuel to the FCP., type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
, ...1 more...
)
fuel_s3_esd
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: Ensure all valves and pneumatic Emergency Shutdown Device (ESD) are off before leaving FCP., type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
, ...1 more...
)
fuel_s3_vent
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: At final shutdown coordinate with scenario manager to vent fuel from prop valves and manifolds at the FCP to relieve pressure. Use the highest prop to do this., type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
, ...1 more...
)
fuel_s3_flags
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: Then close and lock prop valves and close all ID flags down., type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
, ...1 more...
)
fuel_s3_drain
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: At FCP drain system air to close FCP ESDs, type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
, ...1 more...
)
fuel_s3_bleed
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: Shut down pumps at main control panel and bleed air from system to close all pneumatic solenoids., type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
, ...1 more...
)
structural_s2_heat
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: Monitor safety of personnel involved in the scenario including signs of heat exhaustion, fatigue, heat index readings, and manual handling., type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
)
structural_s2_smoke
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: Be aware of other activities on site and monitor direction of smoke flow and vehicle movement, type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
)
petro_s2_heat
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: Monitor safety of personnel involved in the scenario including signs of heat exhaustion, fatigue, heat index readings, and manual handling., type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
)
petro_s2_smoke
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: Be aware of other activities on site and monitor direction of smoke flow and vehicle movement, type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
)
gfs_s3_regulator
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: If disassembling, disconnect regulator from gas cylinder and insert plug, type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
)
gfs_s3_cool
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: Once GFS is cool to touch the Unit is to be returned to place of storage, type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
)
gfs_s3_hazards
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: Detail any hazard found and any issue with the GFS, type: esriFieldTypeString
)
lowrisk_s2_heat
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: Monitor safety of personnel involved in the scenario including signs of heat exhaustion, fatigue, heat index readings, and manual handling., type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
)
lowrisk_s2_smoke
(
nullable: true, editable: true, defaultValue: null, length: 255, alias: Be aware of other activities on site and monitor direction of smoke flow and vehicle movement, type: esriFieldTypeString
, Coded Values:
[yes: Yes]
, [no: No]
, [na: NA]
)